Orion BMS 2 · Wiring & Installation

Everything you need at the bench: how to size and order the BMS, the interactive Main I/O pin-out, output electrical limits, and the safety-critical voltage-tap rules - distilled from Ewert's wiring manual. This is a companion; follow the full manual for every safety-critical detail.

Read firstNever wire or alter battery/tap wiring while the tap connectors are plugged into the BMS - remaining wires can become live through the internal diodes, risking injury, fire and (uncovered) BMS damage. Keep taps disconnected until wiring is complete and verified.
Cell range
24-180
With remotes
324
Max pack
800 V
Main I/O pins
26
CAN interfaces
2
Tap wire
22 AWG
02

Safety - read this first

The essentials from the manual's safety section. Integration must be carried out by a qualified person familiar with lithium-battery safety.

03

Sizing & ordering

Order for the number of cell-tap positions, not just cells. Fuses, safety disconnects and high-impedance busbars mid-pack may force you to skip positions - so size up when unsure. Available in 12-cell increments.

Enter a cell count for a starting BMS size.

A larger unit can run fewer cells (a 108-cell unit works with as few as 4), giving wiring flexibility. Confirm the exact size against the manual and your fuse/disconnect layout.

04

Connectors & pin-outs

The pin-out sheet shows the wire side of each connector. Search or filter the Main I/O pins; tap a row for detail. Click any diagram to enlarge.

Connector locations on the 180-cell Orion BMS 2 unit - Thermistor, Main I/O, status LED, five cell-tap group ports and ground lug
Connector locations on the 180-cell Orion BMS 2 - Thermistor & Main I/O connectors, status LED, five cell-tap group ports (1-3 … 13-15) and ground lug. Click to enlarge.
Orion BMS 2 pin-out diagrams
Full pin-out sheet · wire side · © Ewert Energy. Click to enlarge.

Output electrical limits

Enable / safety outputs are watchdog-backed and can drive a contactor; multi-purpose outputs are signal-level only. * via an external relay/driver.

05

Wiring the voltage taps

The highest-risk part of the install. Read the full "Wiring Voltage Taps" section of the manual before you start.

WarningNever alter any battery wiring - including tightening cell terminals - while the BMS is connected. Disconnect the cell-tap connectors first, and do not reconnect until all wiring is complete and the harnesses have been tested.
Harness & colour codeOrion 2 must use gold-plated tap harnesses (never mix with tinned contacts). Cell group 1 = orange, group 2 = red, group 3 = yellow; cell-group ground wires are black. Cells are numbered from pack-negative upward, one tap per cell plus one negative tap per 12-cell group.
Orion BMS 2 · 23-cell battery tap connections23S lithium pack · tap wiring map, balance-connector pinout & voltage reference
Legend
Pack positive (+)
Balance taps 1–11
Balance taps 12–23
Pack negative (−)
Current sensor
Notes
  • Taps are measured relative to Pack Negative (Pack−).
  • Connect each tap wire to the corresponding point between cells as shown.
  • Pack− must go through the current sensor.
  • Do not connect anything to unused tap inputs.
Voltage reference (vs Pack−)
Tap 0 (Pack−)0 V
Tap 11 × Vcell
Tap 22 × Vcell
Tap 23 (Pack+)23 × Vcell

Vcell = nominal cell voltage · e.g. 3.2 V for LiFePO₄

+CELL 23Tap 23 (Pack+)Tap 23 (Pack+)CELL 22Tap 22Tap 22CELL 21Tap 21Tap 21CELL 12Tap 12Tap 12CELL 11Tap 11Tap 11CELL 10Tap 10Tap 10CELL 9Tap 9Tap 9CELL 8Tap 8Tap 8CELL 7Tap 7Tap 7CELL 6Tap 6Tap 6CELL 5Tap 5Tap 5CELL 4Tap 4Tap 4CELL 3Tap 3Tap 3CELL 2Tap 2Tap 2CELL 1Tap 1Tap 1Tap 0 (Pack negative)Tap 0 (Pack−)Pack −Current sensor
Orion BMS balance connector (24-pin)
PinTapConnects to
1Tap 0 (Pack−)Pack negative (through current sensor)
2Tap 1Between Cell 1 (+) and Cell 2 (+)
3Tap 2Between Cell 2 (+) and Cell 3 (+)
4Tap 3Between Cell 3 (+) and Cell 4 (+)
5Tap 4Between Cell 4 (+) and Cell 5 (+)
6Tap 5Between Cell 5 (+) and Cell 6 (+)
7Tap 6Between Cell 6 (+) and Cell 7 (+)
8Tap 7Between Cell 7 (+) and Cell 8 (+)
9Tap 8Between Cell 8 (+) and Cell 9 (+)
10Tap 9Between Cell 9 (+) and Cell 10 (+)
11Tap 10Between Cell 10 (+) and Cell 11 (+)
12Tap 11Between Cell 11 (+) and Cell 12 (+)
13Tap 12Between Cell 12 (+) and Cell 13 (+)
14Tap 13Between Cell 13 (+) and Cell 14 (+)
15Tap 14Between Cell 14 (+) and Cell 15 (+)
16Tap 15Between Cell 15 (+) and Cell 16 (+)
17Tap 16Between Cell 16 (+) and Cell 17 (+)
18Tap 17Between Cell 17 (+) and Cell 18 (+)
19Tap 18Between Cell 18 (+) and Cell 19 (+)
20Tap 19Between Cell 19 (+) and Cell 20 (+)
21Tap 20Between Cell 20 (+) and Cell 21 (+)
22Tap 21Between Cell 21 (+) and Cell 22 (+)
23Tap 22Between Cell 22 (+) and Cell 23 (+)
24Tap 23 (Pack+)Pack positive (+)
Example · LiFePO₄
Nominal cell (Vcell)
3.2 V
Full pack (23S)
73.6 V
Tap 1
3.2 V
Tap 11
35.2 V
Tap 12
38.4 V
Tap 23 (Pack+)
73.6 V
Always verify tap wiring before powering the BMS. Incorrect wiring can permanently damage the BMS.
Connecting an open-drain output to a relaySample schematic · drive a contactor or relay from a BMS enable output
+5 V to +24 V (Relay Coil Supply) RELAY COIL 175 mACoil Max D1FlybackDiode Open-Drain Output From BMS
Open-drain output sinks current to ground when active (ON). Maximum sink current per output: 175 mA.
Outputs
To Load / System (Switched, N.O.)
To Load / System (Common)
  • The BMS open-drain output turns the relay ON by sinking current through the coil to ground.
  • Use a flyback diode (D1) across the coil to protect the BMS output from voltage spikes.
  • Ensure the relay coil voltage matches your supply (+5 V to +24 V).
  • Maximum coil current (and BMS output sink current) must not exceed 175 mA.
Recommended diode
D1

1N4148, 1N5819 or similar · cathode (stripe) to +V

Fusing the tapsInternal BMS fuses protect against over-/reverse-voltage but not tap-to-tap shorts. If external cell-tap fuses are used, place them as close to the cell terminal as possible, rate them ≤ 5 A and for the full DC working voltage. Series resistors are not permitted as tap current-limiters. Verify every tap with the validation tool or a multimeter before connecting the BMS.
06